1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13: 14: 15: 16: 17: 18: 19: 20: 21: 22: 23: 24: 25: 26: 27: 28: 29: 30: 31: 32: 33: 34: 35: 36: 37: 38: 39: 40: 41: 42: 43: 44: 45: 46: 47: 48: 49: 50: 51: 52: 53: 54: 55: 56: 57: 58: 59: 60: 61: 62: 63: 64: 65: 66: 67: 68: 69: 70: 71: 72: 73: 74: 75: 76: 77: 78: 79: 80: 81: 82: 83: 84: 85: 86: 87: 88: 89: 90: 91: 92: 93: 94: 95: 96: 97: 98: 99:
| string[] vParam = { "ReportParameter1","para_date","para_page", "para_mid1","para_gw_USA1","para_gw_EU1", "para_akz_USA1","para_akz_EU1","para_grenze_kalif1", "para_mid2","para_gw_USA2","para_gw_EU2","para_akz_USA2","para_akz_EU2", "para_grenze_kalif2", "para_mid3","para_gw_USA3","para_gw_EU3","para_akz_USA3","para_akz_EU3", "para_grenze_kalif3", "para_mid4","para_gw_USA4","para_gw_EU4","para_akz_USA4","para_akz_EU4", "para_grenze_kalif4", "para_mid5","para_gw_USA5","para_gw_EU5","para_akz_USA5","para_akz_EU5", "para_grenze_kalif5", "para_mid6","para_gw_USA6","para_gw_EU6","para_akz_USA6","para_akz_EU6", "para_grenze_kalif6", //FUSSFORMULAR "para_ges_freigabe_USA","para_ges_freigabe_EU","para_ueber_gw_kalif", "para_Verteiler2","para_Verteiler3","para_unterschrift1","para_unterschrift2", "para_Verteiler4","para_Verteiler5" };
string vSQL = "SELECT messpos.mpid, messpos.mid, messpos.mvol1, messpos.mvol2, messpos.mvoli, messpos.mvolg, messpos.marea, messpos.marea_e, messpos.mfdap, messpos.mfdap_e, " + "messpos.mfdac, messpos.mcalc, messpos.mdinv, messpos.mdinv_e, messpos.mdinc, messpos.mcomp, messpos.mtrco, messpos.mfdyg , messpos.mfdyg_e, " + "messung.mpart, " + "artikel.arid, artikel.arart, artikel.arnam, artikel.arnum, " + "auftrag.aid, auftrag.aedat, auftrag.aadat, auftrag.abrty, auftrag.abrda, auftrag.ahnam, auftrag.ahnum, auftrag.afnam, auftrag.afnum, auftrag.adnam, " + "auftrag.adnum, auftrag.aaunu, auftrag.aauja, auftrag.acomp, auftraggeber.aufid, auftraggeber.aufna, auftraggeber.aufks " + "FROM messpos " + "LEFT JOIN messung ON messpos.mid = messung.mid " + "LEFT JOIN artikel ON messung.marid = artikel.arid " + "LEFT JOIN auftrag ON artikel.aid = auftrag.aid " + "LEFT JOIN auftraggeber ON auftraggeber.aufid = auftrag.aufid " + "WHERE artikel.aid = " + mCtrl.mDataSet.mAuftrag.mAID.ToString() + " AND ( messung.mpart = " + "'" + aElem + "'"+ " OR messung.mpart = " + "'" +"TR_"+aElem + "'"+" ) "+ " AND artikel.arid = " + aArid + "ORDER BY messpos.mpid ";
mDS = mCtrl.searchDataSet(vSQL); mDT = mDS.Tables[0];
if (mDS.Tables[0].Rows.Count > 0) { mPrintCheck = true;
if (aElem == "BLEI") { if (mEng == true) { mCryRpt.Load(Directory.GetCurrentDirectory() + mFolder + "\\Report_Bleilaessigkeit_En.rpt"); } else { mCryRpt.Load(Directory.GetCurrentDirectory() + mFolder + "\\Report_Bleilaessigkeit_Deu.rpt"); } } else if (aElem == "CAD") { if (mEng == true) { mCryRpt.Load(Directory.GetCurrentDirectory() + mFolder + "\\Report_cadmium_En.rpt"); } else { mCryRpt.Load(Directory.GetCurrentDirectory() + mFolder + "\\Report_cadmium_Deu.rpt"); } }
mCryRpt.SetDataSource(mDT);
ParameterFieldDefinitions[] crParameterFieldDefinitions = new ParameterFieldDefinitions[vParam.Length]; ParameterFieldDefinition[] crParameterFieldDefinition = new ParameterFieldDefinition[vParam.Length]; ParameterValues[] crParameterValues = new ParameterValues[vParam.Length]; ParameterDiscreteValue[] crParameterDiscreteValue = new ParameterDiscreteValue[vParam.Length];
for (int i = 0; i < vParam.Length; i++) { crParameterValues[i] = new ParameterValues(); crParameterDiscreteValue[i] = new ParameterDiscreteValue();
//Hier werden einfach nur die Parameterfelder befüllt. Wenn zum Beispiel vParam.Length 5 ist dann läuft er hier 5 mal rein und wählt jedes mal eine andere Case anweisung aus. Er befüllt jeden Parameter nur einmal! crParameterDiscreteValue[i].Value = checkParam_LeachPage(i, aElem, aArid, aCurArid);
crParameterFieldDefinitions[i] = mCryRpt.DataDefinition.ParameterFields; crParameterFieldDefinition[i] = crParameterFieldDefinitions[i][vParam[i]]; crParameterValues[i] = crParameterFieldDefinition[i].CurrentValues;
crParameterValues[i].Clear(); crParameterValues[i].Add(crParameterDiscreteValue[i]); crParameterFieldDefinition[i].ApplyCurrentValues(crParameterValues[i]); }
mCryRpt.PrintToPrinter(1, false, 0, 0); |